| Standard Range |
| Testing Range: air pressure:0-120kpa Temperature -40-80°C (customized for option) |
| Technical Index |
| Analog Signal output |
4~20mA 0~5VDC 0~10VDC |
| Digital Signal output |
RS485 output (Modbus protocol) |
| Working Voltage |
10-30VDC Note: 0-10VDC output (limited to 24VDC power supply) |
| Power consumption |
Analog signal (voltage/current maximum power consumtion 1.2w) |
| |
Digital signal maximum power consumption ≤0.4w |
| Accuracy |
Air Pressure ±0.15kpa (25°C) Temperature:±0.5°C(25°C) |
| Long term stability |
Air pressure -0.1kpa/year Temperauture ≤0.1°C/year |
| |
Temperauture ≤0.1°C/year |
| Response Time |
≤1S |
| Working Environment |
-20-+60°C 0%RH-80%RH |
| Digital output: Device address |
1-255 can be set, the default is 1 |
| Device baud rate |
2400 4800 9600 for option |
| Byte format |
8 bit data bit, 1 stop position, no parity |
| Electrical connection |
Direct Lead |